Medicine Devices / AL Systeme

deutsch
subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link
subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link
subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link
subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link
subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link
subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link
subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

Veterinary

Home

THE  SEMI-AUTOMATED VETERINARY HEMATOLOGICAL  ANALYSER (CELLCOUNTER) MEDIVET WITH SEPARATE DILUTER FOR MANUAL DILUTION WHILE MEASURING 
Determination of the Parameters: WBC, RBC, HGB, HCT, MCV, PLT  
Programmed for 8 different animals
Capacity per hour: about 30 samples

TECHNICAL DATA 
 
Methods:
Electronic, impedance principle
(change of  electrical  resistance),
colorimetric haemoglobine determination
by  built-in photometer
 
Counting time:
11 seconds 
 
Volume unit:
Liquid manometer with electronic detectors 
 
Transducer:
Single 80 µm capillary 
 
Display:
LCD 64-digit alpha-numeric 
 
Measurement Value 
Processing:

Microprocessor 

Self diagnostic package:
Displays disfunctions and suggests solutions 
 
Sample Volume:
40 µl 
 
Reagent consumption:
Isotonic diluent: 20 ml per sample Hemolyzing reagent: 120 µl per sample 
 
Calibration:
keyboard calibration possible

CV-values:        
RBC :    < 1,5 percent 
WBC:    < 2,0 percent 
HGB:    < 1,0 percent 
PLT:     < 5,0 percent 

Dimensions:
width:   290 mm 
depth:   355 mm 
height:  350 mm 
 
Weight:
13 kg 
 
Power consumption:
max 50 W 
 
Voltage (standard):
110 / 220 V, 50 / 60 Hz 
 
Printer output:
on request (not standard) 

NO PERIODIC MAINTENANCE  !!  

THE  AUTOMATED VETERINARY HEMATOLOGICAL  ANALYSER MEDIVET 4000 WITH AUTOMATIC DILUTER
Determination of the Parameters: WBC, RBC, HGB, HCT, MCV, PLT,  MCH, MCHC, MPV, PCT,
LYM%, LYM#, MID%-MID#-GRAN%, GRAN#, RCDW, LCDW, RDW-SD, RDW-CV, PDW
Programmed for 9 different animals

Capacity per hour: about 50 samples

TECHNICAL DATA 
 
Methods:
Electronic, impedance principle
(change of  electrical  resistance),
colorimetric haemoglobine determination
by  built-in photometer
 
Counting time:
RBC ~ 11 seconds 
WBC ~ 8 seconds 
 
Volume unit:
Liquid manometer with electronic detectors 
 
Transducer:
RBC 80 µm capillary 
WBC 100 µm capillary 
 
Display:
Big sized LCD
 
Measurement Value 
Processing:

Microprocessor 

Self diagnostic package:
Displays disfunctions and suggests solutions 
 
Sample Volume:
20 µl 
 
Reagent consumption:
Isotonic diluent: 20 ml per sample Hemolyzing reagent: 0.6 ml per sample 
 
Calibration:
Keyboard calibration possible

CV-values:        
RBC :    < 1,5 percent 
WBC:    < 2,0 percent 
HGB:    < 1,0 percent 
PLT:     < 6,0 percent 

Dimensions:
width:   490 mm 
depth:   335 mm 
height:  350 mm 
 
Weight:
30 kg 
 
Power consumption:
max 200 W 
 
Voltage (standard):
110 / 220 V, 50 Hz 
 
Printer output:
Serial port (RS 232)
Parallel port for printer 
 

©2005 Medicine Devices